Bridges of constant deck width |
|
Number of girders greater than or equal to 4 |
|
Parallel girders with approximately equal
spacing |
|
Span length must exceed 2.5 times the deck width |
|
Plan curvature of less than 12 degrees in any
one span |
|
|
|
|
|
Conduct a detailed study of limits imposed by
the 1998 AASHTO LRFD Specifications |
|
Investigate whether these limits can be
broadened to include typical box-girder bridge in California |
|
Emphasis is placed on these three parameters: |
|
Non-prismatic cross-sections |
|
Plan aspect ratio (length/width) less than 2.5 |
|
Plan curvature > 12 degrees in any one span |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The current AASHTO LRFD distribution factor for
box-girder bridges is conservative with respect to the design bending
moment and shear force, even for bridges outside their range of
applicability |
|
Plan aspect ratio may be expanded to L/W >1
instead of the current limit of L/W > 2.5 |
|
The current LRFD distribution factor may be used
for non-prismatic bridges with flare up to the limit of 1-in-15 or 6.6% |
|
The plan curvature limit of 12 degrees appears
to be unnecessary, and the limit may be increased to about 35 degrees |
|